Option/ Additional Information |
Possible cause | Remedy |
---|---|---|
Heater is in fault lock-out mode | Deactivate
fault lock-out in accordance with operating instructions; determine cause and eliminate |
|
Break in the power supply to the heater | Check if voltage >11.5V is present at heater and across Pin1 of connector X2 (2-pin connector adjacent to 6-pin connector X1) | |
Summer/winter switch in summer position | Turn switch to winter position (flame symbol) | |
Discharged battery | Charge battery | |
Defective fuse | Replace fuse | |
with digital timer | Defective digital timer | Disconnect
6-pin connector X1 from heater. Press instant heat button (button with flame symbol) on the digital timer. Display must be illuminated and the voltage at pin 1 (6-pin connector X1) must be >11.5V |
with digital timer | Break in the power supply to the digital timer | Disconnect
connector from the digital timer. Check if > 11,5 V voltage is present across the red and brown wires of the connector. Check fuse 1 A and cables wires |
with telestart T70 | Transmitter in the ventilation mode | Set mode in accordance with T70 operating instructions |
with telestart T60 / 70 | Transmitter not allocated to receiver | Allocate transmitter in accordance with installation / operating installations |
with telestart T60 / 70 | Insufficient voltage of batteries in transmitter | Replace batteries |
with telestart T60 / 70 | Batteries incorrectly positioned in battery compartment | Insert batteries in battery compartment in accordance with operating instructions |
with telestart T60 / 70 | Defective transmitter or receiver | Applies
only to external receiver! Disconnect 6-pin connector X1 from heater. Apply 12V across Pin 1 (only the combustion air fan motor is allowed to be operating) |