Option/ Additional Information |
Possible cause | Remedy |
---|---|---|
Heater is in a fault lock-out mode | Deactivate fault lock-out in accordance with operating instructions; determine cause and eliminate |
|
Break in the power supply to the heater | Check if voltage >11.5V is present at heater and across Pin1 of connector X15 (2-pin connector adjacent to 6-pin connector X14) | |
Summer/winter switch in summer position | Turn switch to winter position (flame symbol) | |
Discharged battery | Charge battery | |
Defective fuse | Replace fuse | |
with digital timer | Defective digital timer | Disconnect 6-pin connector X14 from heater. Press instant heat button (button with flame symbol) on the digital timer. Display must be illuminated and voltage across Pin 1 (6-pin connector X14) must be >7 V |
with digital timer | Break in the power supply to the digital timer | Disconnect connector from the digital timer. Check if > 11,5 V voltage is present across the red and brown wires of the connector. Check fuse 1 A and cables wires. |
with telestart T70 | Transmitter in the ventilating mode | Set mode in accordance with T70 operating instructions |
with telestart T60 / 70 | Transmitter has not been allcoated to receiver | Allocate transmitter in accordance with installation/ operating instructions |
with telestart T60 / 70 | Voltage of batteries in transmitter too low | Replace batteries |
with telestart T60 / 70 | Incorrectly installed batteries | Install batteries in battery compartment in accordance with operating instructions |
with telestart T60 / 70 | Defective transmitter or receiver | Applies only to external receiver! Disconnect 6-pin connector X14 from heater. Apply 12V across Pin 1 (only the combustion air fan motor is allowed to be operating) |